OpenAlex Citation Counts

OpenAlex Citations Logo

OpenAlex is a bibliographic catalogue of scientific papers, authors and institutions accessible in open access mode, named after the Library of Alexandria. It's citation coverage is excellent and I hope you will find utility in this listing of citing articles!

If you click the article title, you'll navigate to the article, as listed in CrossRef. If you click the Open Access links, you'll navigate to the "best Open Access location". Clicking the citation count will open this listing for that article. Lastly at the bottom of the page, you'll find basic pagination options.

Requested Article:

Electrochemical Glucose Sensing: Is There Still Room for Improvement?
Emilia Witkowska Nery, Magdalena Kundys, Paulina S. Jeleń, et al.
Analytical Chemistry (2016) Vol. 88, Iss. 23, pp. 11271-11282
Closed Access | Times Cited: 266

Showing 1-25 of 266 citing articles:

A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors
Siva Kumar Krishnan, Eric J. Singh, Pragya Singh, et al.
RSC Advances (2019) Vol. 9, Iss. 16, pp. 8778-8881
Open Access | Times Cited: 670

Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Hazhir Teymourian, Abbas Barfidokht, Joseph Wang
Chemical Society Reviews (2020) Vol. 49, Iss. 21, pp. 7671-7709
Closed Access | Times Cited: 664

Beyond the lateral flow assay: A review of paper-based microfluidics
Cody S. Carrell, Alyssa A. Kava, Michael Nguyen, et al.
Microelectronic Engineering (2019) Vol. 206, pp. 45-54
Open Access | Times Cited: 293

Biofuel powered glucose detection in bodily fluids with an n-type conjugated polymer
David Ohayon, Georgios Nikiforidis, Achilleas Savva, et al.
Nature Materials (2019) Vol. 19, Iss. 4, pp. 456-463
Closed Access | Times Cited: 255

MXene Titanium Carbide-based Biosensor: Strong Dependence of Exfoliation Method on Performance
Hui Ling Chia, Carmen C. Mayorga‐Martinez, Nikolas Antonatos, et al.
Analytical Chemistry (2020) Vol. 92, Iss. 3, pp. 2452-2459
Closed Access | Times Cited: 200

Electronic Tongue—A Tool for All Tastes?
Marta Podrażka, Ewa Bączyńska, Magdalena Kundys, et al.
Biosensors (2017) Vol. 8, Iss. 1, pp. 3-3
Open Access | Times Cited: 189

Fully Stretchable Capillary Microfluidics-Integrated Nanoporous Gold Electrochemical Sensor for Wearable Continuous Glucose Monitoring
Chan Wool Bae, Phan Tan Toi, Bo Yeong Kim, et al.
ACS Applied Materials & Interfaces (2019) Vol. 11, Iss. 16, pp. 14567-14575
Closed Access | Times Cited: 189

In Vivo Biosensing: Progress and Perspectives
Guoxin Rong, Simon R. Corrie, Heather A. Clark
ACS Sensors (2017) Vol. 2, Iss. 3, pp. 327-338
Open Access | Times Cited: 177

Preparation of paper-based devices for reagentless electrochemical (bio)sensor strips
Stefano Cinti, Danila Moscone, Fabiana Arduini
Nature Protocols (2019) Vol. 14, Iss. 8, pp. 2437-2451
Closed Access | Times Cited: 149

Soft Wearable Healthcare Materials and Devices
Quanxia Lyu, Shu Gong, Jialiang Yin, et al.
Advanced Healthcare Materials (2021) Vol. 10, Iss. 17
Open Access | Times Cited: 122

Review—Electrochemistry and Other Emerging Technologies for Continuous Glucose Monitoring Devices
Saroj Kumar Das, Kavya K. Nayak, P. R. Krishnaswamy, et al.
ECS Sensors Plus (2022) Vol. 1, Iss. 3, pp. 031601-031601
Open Access | Times Cited: 111

Pt/MXene-Based Flexible Wearable Non-Enzymatic Electrochemical Sensor for Continuous Glucose Detection in Sweat
Quanfu Li, Xu Chen, Hai Wang, et al.
ACS Applied Materials & Interfaces (2023) Vol. 15, Iss. 10, pp. 13290-13298
Closed Access | Times Cited: 110

Chameleon-inspired multifunctional plasmonic nanoplatforms for biosensing applications
Yasamin Ziai, Francesca Petronella, Chiara Rinoldi, et al.
NPG Asia Materials (2022) Vol. 14, Iss. 1
Open Access | Times Cited: 74

Smart Contact Lenses as Wearable Ophthalmic Devices for Disease Monitoring and Health Management
Hunkyu Seo, Won Gi Chung, Yong Won Kwon, et al.
Chemical Reviews (2023) Vol. 123, Iss. 19, pp. 11488-11558
Open Access | Times Cited: 59

Artificial intelligence biosensors for continuous glucose monitoring
Xiaofeng Jin, Andrew Cai, Tailin Xu, et al.
Interdisciplinary materials (2023) Vol. 2, Iss. 2, pp. 290-307
Open Access | Times Cited: 49

A non-invasive wearable sweat biosensor with a flexible N-GQDs/PANI nanocomposite layer for glucose monitoring
Yu-Chi Lin, Mia Rinawati, Ling‐Yu Chang, et al.
Sensors and Actuators B Chemical (2023) Vol. 383, pp. 133617-133617
Closed Access | Times Cited: 48

Electrochemical sensing of analytes in saliva: Challenges, progress, and perspectives
Ana Gomez Cardoso, Herlys Viltres, Greter A. Ortega, et al.
TrAC Trends in Analytical Chemistry (2023) Vol. 160, pp. 116965-116965
Closed Access | Times Cited: 44

Non-invasive wearable electrochemical sensors for continuous glucose monitoring
Sameera Sh. Mohammed Ameen, Khalid M. Omer, Fotouh R. Mansour, et al.
Electrochemistry Communications (2025), pp. 107894-107894
Open Access | Times Cited: 2

Nonenzymatic Wearable Sensor for Electrochemical Analysis of Perspiration Glucose
Xiaofei Zhu, Yinhui Ju, Jian Chen, et al.
ACS Sensors (2018) Vol. 3, Iss. 6, pp. 1135-1141
Closed Access | Times Cited: 139

Single-step fabrication of an integrated 3D-printed device for electrochemical sensing applications
Vassiliki Katseli, Anastasios Economou, Christos Kokkinos
Electrochemistry Communications (2019) Vol. 103, pp. 100-103
Open Access | Times Cited: 132

Contact-Lens Biosensors
R. Tseng, Ching-Chuen Chen, Sheng‐Min Hsu, et al.
Sensors (2018) Vol. 18, Iss. 8, pp. 2651-2651
Open Access | Times Cited: 127

Electrochemical sensors targeting salivary biomarkers: A comprehensive review
Veerappan Mani, Tutku Bedük, Walaa Khushaim, et al.
TrAC Trends in Analytical Chemistry (2020) Vol. 135, pp. 116164-116164
Closed Access | Times Cited: 124

Three-Dimensional Copper Foam Supported CuO Nanowire Arrays: An Efficient Non-enzymatic Glucose Sensor
Xiangjian Liu, Wenxiu Yang, Lulu Chen, et al.
Electrochimica Acta (2017) Vol. 235, pp. 519-526
Closed Access | Times Cited: 123

Challenges and perspectives in continuous glucose monitoring
Benjamin Jasha van Enter, Elizabeth von Hauff
Chemical Communications (2018) Vol. 54, Iss. 40, pp. 5032-5045
Open Access | Times Cited: 119

Influence of mesoporous defect induced mixed-valent NiO (Ni2+/Ni3+)-TiO2 nanocomposite for non-enzymatic glucose biosensors
Saravanan Rajendran, Devaraj Manoj, Kumar Raju, et al.
Sensors and Actuators B Chemical (2018) Vol. 264, pp. 27-37
Closed Access | Times Cited: 109

Page 1 - Next Page

Scroll to top