
OpenAlex is a bibliographic catalogue of scientific papers, authors and institutions accessible in open access mode, named after the Library of Alexandria. It's citation coverage is excellent and I hope you will find utility in this listing of citing articles!
If you click the article title, you'll navigate to the article, as listed in CrossRef. If you click the Open Access links, you'll navigate to the "best Open Access location". Clicking the citation count will open this listing for that article. Lastly at the bottom of the page, you'll find basic pagination options.
Requested Article:
Posterior cruciate ligament retention with medial ball-in-socket conformity promotes internal tibial rotation and knee flexion while providing high clinical outcome scores
Saúl Pacheco Elorza, Ed O’Donnell, Connor Delman, et al.
The Knee (2023) Vol. 43, pp. 153-162
Closed Access | Times Cited: 10
Saúl Pacheco Elorza, Ed O’Donnell, Connor Delman, et al.
The Knee (2023) Vol. 43, pp. 153-162
Closed Access | Times Cited: 10
Showing 10 citing articles:
A TKA can be kinematically aligned without restrictions: Current evidence
Alexander J. Nedopil, Stephen M. Howell, Maury L. Hull, et al.
Knee Surgery Sports Traumatology Arthroscopy (2024) Vol. 32, Iss. 6, pp. 1354-1358
Closed Access | Times Cited: 6
Alexander J. Nedopil, Stephen M. Howell, Maury L. Hull, et al.
Knee Surgery Sports Traumatology Arthroscopy (2024) Vol. 32, Iss. 6, pp. 1354-1358
Closed Access | Times Cited: 6
Simulated Partial and Complete Resection of the Posterior Cruciate Ligament in Medially Conforming Total Knee Arthroplasty Causes a Graded Reduction in Femoral Rollback and Increase in Posterior Tibial Sag: A Computational Study
Reza Pourmodheji, Cynthia A. Kahlenberg, Brian P. Chalmers, et al.
The Journal of Arthroplasty (2025)
Closed Access
Reza Pourmodheji, Cynthia A. Kahlenberg, Brian P. Chalmers, et al.
The Journal of Arthroplasty (2025)
Closed Access
Retention of the posterior cruciate ligament stabilizes the medial femoral condyle during kneeling using a tibial insert with ball-in-socket medial conformity
Greg Harbison, Ed O’Donnell, Saúl Pacheco Elorza, et al.
International Orthopaedics (2024) Vol. 48, Iss. 9, pp. 2395-2401
Closed Access | Times Cited: 2
Greg Harbison, Ed O’Donnell, Saúl Pacheco Elorza, et al.
International Orthopaedics (2024) Vol. 48, Iss. 9, pp. 2395-2401
Closed Access | Times Cited: 2
A New Handheld Tool to Select the Correct Tibial Insert Thickness by Measuring the Force to Push a Trial Insert Into Position During Total Knee Arthroplasty Surgery
Gabriel Santana, Stephen M. Howell, Maury L. Hull
Journal of Medical Devices (2024) Vol. 18, Iss. 1
Closed Access | Times Cited: 1
Gabriel Santana, Stephen M. Howell, Maury L. Hull
Journal of Medical Devices (2024) Vol. 18, Iss. 1
Closed Access | Times Cited: 1
The peak force to push a trial tibial insert into position cannot be used to select the correct thickness in total knee arthroplasty
Gabriel Santana, Stephen M. Howell, Maury L. Hull
Archives of Orthopaedic and Trauma Surgery (2024) Vol. 144, Iss. 6, pp. 2767-2773
Closed Access | Times Cited: 1
Gabriel Santana, Stephen M. Howell, Maury L. Hull
Archives of Orthopaedic and Trauma Surgery (2024) Vol. 144, Iss. 6, pp. 2767-2773
Closed Access | Times Cited: 1
A new tibial insert design with ball-in-socket medial conformity and posterior cruciate ligament retention has low tibial baseplate migration after unrestricted kinematically aligned total knee arthroplasty: a cohort study using radiostereometric analysis
Abigail E. Niesen, Pranav A. Tirumalai, Stephen M. Howell, et al.
Acta Orthopaedica (2024) Vol. 95
Open Access | Times Cited: 1
Abigail E. Niesen, Pranav A. Tirumalai, Stephen M. Howell, et al.
Acta Orthopaedica (2024) Vol. 95
Open Access | Times Cited: 1
Analysis of Variation in Sagittal Curvature of the Femoral Condyles
E. Winslow, Xuanbei Pan, Maury L. Hull
Journal of Biomechanical Engineering (2024) Vol. 146, Iss. 11
Closed Access
E. Winslow, Xuanbei Pan, Maury L. Hull
Journal of Biomechanical Engineering (2024) Vol. 146, Iss. 11
Closed Access
An Insert Goniometer Can Help Select the Optimal Insert Thickness When Performing Kinematically Aligned Total Knee Arthroplasty with a Medial 1:1 Ball-in-Socket and Lateral Flat Surface Insert and Posterior Cruciate Ligament Retention
Sahil Sanghavi, Alexander J. Nedopil, Stephen M. Howell, et al.
Bioengineering (2024) Vol. 11, Iss. 9, pp. 910-910
Open Access
Sahil Sanghavi, Alexander J. Nedopil, Stephen M. Howell, et al.
Bioengineering (2024) Vol. 11, Iss. 9, pp. 910-910
Open Access
Kinematic Approach
Alexander J. Nedopil, Sahil Sanghavi, Stephen M. Howell, et al.
(2024), pp. 117-131
Closed Access
Alexander J. Nedopil, Sahil Sanghavi, Stephen M. Howell, et al.
(2024), pp. 117-131
Closed Access
Does the posterior tibial slope in caliper-verified unrestricted kinematically aligned TKA using manual instruments match the slope in the contralateral healthy knee and improve function?
Alexander J. Nedopil, Stefano Ghiradelli, Stephen M. Howell, et al.
The Knee (2024) Vol. 53, pp. 62-68
Closed Access
Alexander J. Nedopil, Stefano Ghiradelli, Stephen M. Howell, et al.
The Knee (2024) Vol. 53, pp. 62-68
Closed Access