
OpenAlex is a bibliographic catalogue of scientific papers, authors and institutions accessible in open access mode, named after the Library of Alexandria. It's citation coverage is excellent and I hope you will find utility in this listing of citing articles!
If you click the article title, you'll navigate to the article, as listed in CrossRef. If you click the Open Access links, you'll navigate to the "best Open Access location". Clicking the citation count will open this listing for that article. Lastly at the bottom of the page, you'll find basic pagination options.
Requested Article:
Non-linear explicit micro-FE models accurately predict axial pull-out force of cortical screws in human tibial cortical bone
Marzieh Ovesy, Juan Diego Silva-Henao, James Fletcher, et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (2021) Vol. 126, pp. 105002-105002
Closed Access | Times Cited: 10
Marzieh Ovesy, Juan Diego Silva-Henao, James Fletcher, et al.
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (2021) Vol. 126, pp. 105002-105002
Closed Access | Times Cited: 10
Showing 10 citing articles:
Finite element analysis and experimental verification of press-fit peg push-in and pull-out in trabecular bone analogue
Xiaoyi Min, David Heath, Azmi Rahman, et al.
Results in Engineering (2025), pp. 104029-104029
Open Access
Xiaoyi Min, David Heath, Azmi Rahman, et al.
Results in Engineering (2025), pp. 104029-104029
Open Access
Optimization of Primary Screw Stability in Trabecular Bone Using Neural Network-Based Models
Yijun Zhou, Benedikt Helgason, Stephen J. Ferguson, et al.
Computer Methods and Programs in Biomedicine (2025) Vol. 264, pp. 108720-108720
Open Access
Yijun Zhou, Benedikt Helgason, Stephen J. Ferguson, et al.
Computer Methods and Programs in Biomedicine (2025) Vol. 264, pp. 108720-108720
Open Access
Screw pull-out force predictions in porcine radii using efficient nonlinear µFE models including contact and pre-damage
Pia Stefanek, Juan Diego Silva-Henao, Victoria Fiedler, et al.
Frontiers in Bioengineering and Biotechnology (2025) Vol. 13
Open Access
Pia Stefanek, Juan Diego Silva-Henao, Victoria Fiedler, et al.
Frontiers in Bioengineering and Biotechnology (2025) Vol. 13
Open Access
Bone mineral density surrounding the screw thread predicts the risk of pedicle screw loosening
Yanxia Jiang, Wei Yi, Yuxuan Liu, et al.
Journal of Biomechanics (2025) Vol. 181, pp. 112542-112542
Closed Access
Yanxia Jiang, Wei Yi, Yuxuan Liu, et al.
Journal of Biomechanics (2025) Vol. 181, pp. 112542-112542
Closed Access
Developing and Validating a Model of Humeral Stem Primary Stability, Intended for In Silico Clinical Trials
Ghislain Maquer, Christine Mueri, Adam Henderson, et al.
Annals of Biomedical Engineering (2024) Vol. 52, Iss. 5, pp. 1280-1296
Closed Access | Times Cited: 2
Ghislain Maquer, Christine Mueri, Adam Henderson, et al.
Annals of Biomedical Engineering (2024) Vol. 52, Iss. 5, pp. 1280-1296
Closed Access | Times Cited: 2
Validated, high-resolution, non-linear, explicit finite element models for simulating screw - bone interaction
Yijun Zhou, Benedikt Helgason, Stephen J. Ferguson, et al.
Biomedical Engineering Advances (2024) Vol. 7, pp. 100115-100115
Open Access | Times Cited: 2
Yijun Zhou, Benedikt Helgason, Stephen J. Ferguson, et al.
Biomedical Engineering Advances (2024) Vol. 7, pp. 100115-100115
Open Access | Times Cited: 2
Critical loss of primary implant stability in osteosynthesis locking screws under cyclic overloading
Juan Diego Silva-Henao, Sophie Schober, Dieter H. Pahr, et al.
Medical Engineering & Physics (2024) Vol. 126, pp. 104143-104143
Open Access | Times Cited: 2
Juan Diego Silva-Henao, Sophie Schober, Dieter H. Pahr, et al.
Medical Engineering & Physics (2024) Vol. 126, pp. 104143-104143
Open Access | Times Cited: 2
Comparison of simplified bone-screw interface models in materially nonlinear μFE simulations
Pia Stefanek, Dieter H. Pahr, Alexander Synek
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (2024) Vol. 157, pp. 106634-106634
Open Access | Times Cited: 1
Pia Stefanek, Dieter H. Pahr, Alexander Synek
Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials (2024) Vol. 157, pp. 106634-106634
Open Access | Times Cited: 1
Bicortical Compression and Construct Stability with Variable Pitch Locking Screws in Cadaveric Specimens
Zachary Koroneos, Shelby Alwine, Peter Tortora, et al.
Journal of Orthopaedic Trauma (2024) Vol. 38, Iss. 10, pp. e339-e346
Closed Access | Times Cited: 1
Zachary Koroneos, Shelby Alwine, Peter Tortora, et al.
Journal of Orthopaedic Trauma (2024) Vol. 38, Iss. 10, pp. e339-e346
Closed Access | Times Cited: 1
Improving the mechanical properties and corrosion resistance of biodegradable Mg–Zn–Ca–Mn alloy bone screw through structural optimization
Ziyue Jiao, Shaoyuan Lyu, Wei Li, et al.
Journal of Materials Research and Technology (2022) Vol. 21, pp. 1442-1453
Open Access | Times Cited: 7
Ziyue Jiao, Shaoyuan Lyu, Wei Li, et al.
Journal of Materials Research and Technology (2022) Vol. 21, pp. 1442-1453
Open Access | Times Cited: 7